Standard Details Contents Page
Tempe Supplement to the Maricopa Association of Governments Uniform Standard
Specifications
for Public Works Construction. Click here for "Table
of Contents" or "Undivided
Version".
All files require
Adobe Acrobat
Reader software to read "PDF" files. Which can be obtained by clicking the
underlined text and following download procedures.
100 SERIES GENERAL INFORMATION
T-115 General Information
200 SERIES WATER INFORMATION
T-115
T-210
T-211
T-212
T-212A
T-213
T-214
T-215
T-216
T-217 |
General Information
Fire Sprinkler Riser Detail Backflow Prevention
Pressure Vacuum Breaker Backflow
Assembly
Water Meter & Service Installation
1 1/2" & 2" Meter Installation
Backflow Assembly Installation 3/4" - 2 1/2"
Backflow Prevention Assembly Installation 3" - 10" and (Valve setter Option)
Standard Prevention Assemble
Valve Vault Installation for
Existing Butterfly Valve
Waterline Extension
for Building Fire Sprinklers |
300 SERIES STREET INFORMATION
|
T-115
T-303
T-304
T-305
T-306
T-311
T-312
T-313
T-314
T-315
T-316
T-317
T-319
T-320
T-321
T-322
T-324
T-326
T-328
T-329
T-345
T-347
T-348
T-349
T-350
T-351
T-353-1
T-353-2
T-353-3
T-354
T-356
T-360
|
General Information
Depth of Base
Course ( L-1 Streets )
Depth of Base Course ( L-2 and C-1
Streets )
Depth of Base Course ( C-2 Streets
)
Depth of Base Course ( A-1, A-2 and
Heavy Industrial Streets )
Street Cross-Section ( L-1, L-2 )
Collector Cross-Section ( C-1, C-2 )
Arterial Street Cross-Section ( A-1
)
Street Intersection
Street Cross-Section (Ribbon Curb)
Street Cross-Section ( Ribbon Curb.
)
Street Cross-Section ( Ribbon Curb.
)
Return Type Driveways
Driveways Entrances
Private Entrance with Median Island
Mid- Block Ramp for 4", 6"
and 7" Curb
Diagonal Ramps - Type "A"
Not Preferred - Use Only Where Directional Ramps Are Not
Possible
Blended Transition Ramps - Type "B"
Not Preferred - Use Only Where Directional Ramps Are Not Possible
Preferred - Directional Sidewalk Ramp Detail 25', 30'
Radius Curb Returns
Detectable Warning
Typical Sidewalk Alignment
Blended Mid-block Ramp For 4", 6" and 7" Curb
Sidewalk Scoop
Ramp Detail for Return Type Driveway
Sidewalk and Ramp at Street
Intersection, Where Directional Ramps Are Not Possible
Vertical Curb Returns on Ribbon Curb
streets
South Tempe Overlay District
Sidewalk Details
Brick Sidewalk and Tree Grate
Brick Sidewalk and Tree Grate
Concrete/Brick Driveway at Brick Sidewalk
Slotted Drain
Striping for Residential Speed
Hump
Signage/Striping for ADA Accessible Parking Spaces |
400 SERIES UTILITY INFORMATION
|
T-115
T-431
T-432
T-433
T-434
T-435
T-436
T-437
T-438
T-439
T-440
T-441
T-445
T-446
T-450
T-452
T-453
T-454
T-455 |
General Information
STD. Utility Location ( 20' Alley )
STD. Utility Location ( 16' Alley )
STD. Utility Location ( 12' Alley )
STD. Utility Location ( 16' Easement
)
STD. Utility Location ( 12' Easement
)
STD. Utility Location ( C-2 Comm.
& Mid-Section Collector Streets )
STD. Utility Location ( C-1
Residential Collector Street )
STD. Utility Location ( L-1 Single
Local Streets )
STD. Utility Location ( A-1 Arterial
Street )
STD. Utility Fixture & Conduit
Placement
Electric Underground Junction Box
Valve Grade Adjustment
Manhole Grade Adjustment
Trench Backfill and Pavement
Replacement
In-Ground Reinforced Electrical Irrigation Pull Boxes (
Parks )
Traffic Signal Pull Boxes
Control Sampling Vault
Engineered Utility Bore |
500 SERIES TRAFFIC INFORMATION
T-115
T-530
T-540
T-541
T-544
T-545
T-548
T-550
T-551
T-552
T-553
T-554
T-555
T-556
T-557
T-558
T-559
T-560
T-561
T-562
T-570-1
T-570-2
T-571-1
T-571-2
T-572-1
T-572-2
T-573-1
T-573-2
T-575
T-576
T-577
T-578 |
General Information
Modified ADOT Signal Pole and Mast Arm With Decorative Luminair for Downtown
Installation
Modular Pole 'Q' - 25' Mast Arm
Modular Pole 'J' - 25' Mast Arm
Modular Pole 'Q' - 30' Mast Arm
Modular Pole 'J' - 30' Mast Arm
Modular Pole 'Q' - 50' Mast Arm
Modular Pole 'Q' - 45' Mast Arm
Modular Pole 'J' - 45' Mast Arm
Modular Pole 'Q' - 40' Mast Arm
Modular Pole 'J' - 40' Mast Arm
Modular Pole 'Q' - 35' Mast Arm
Modular Pole 'J' - 35' Mast Arm
Modular Pole 'F' - 20' Mast Arm
Modular Pole 'E' - 20' Mast Arm
Modular Pole 'A-1'
Modular Pole 'A-2'
Modular Pole Mast Arm Connection
Modular Signal Add-On Structures
Modular Signal Mast Arm Sign
Mounting Standards
Traffic Signal Foundation
Detail
Foundation for Type "A" Modular (No Mast Arm)
Traffic Signal Foundation
Detail
Foundation for Type "A" Modular (No Mast Arm)
Traffic Signal Foundation
Detail Foundation for Modular
20,25,30,35,40 Mast Arm
Structures
Traffic Signal Foundation
Detail Foundation for Modular
20,25,30,35,40 Mast Arm Structures
Traffic Signal Foundation
Detail
for Modular 45 Mast Arm Structure
Traffic Signal Foundation
Detail
for Modular 45 Mast Arm Structure
Traffic Signal
Foundation Detail, For Modular 50 Mast Arm Structure
Traffic Signal
Foundation Detail, For Modular 50 Mast Arm Structure
Traffic Loop
Detector Detail
Bicycle Loop
Detector Detail
Bicycle Push
Button and Pole Detail
Bicycle Rack
Detail |
600 SERIES STREET LIGHTING
T-115
T-645
T-650
T-651-1
T-651-2
T-652-1
T-652-2
T-653-1
T-653-2
T-654-1
T-654-2
T-654-3
T-654-4
T-654-5
T-654-6
T-654-7
T-654-9
T-654-10
T-654-11
T-654-12
T-655
T-656-1
T-656-2
T-656-3
T-657
T-658 |
General Information
Tempe Special District Lighting
Street
Light Pull Box & Connection Details
Stream-Line Steel Pole Details
Stream-Line Steel Pole Details
Architectural Street Light
Architectural Street Light
Special District Street Light
Special District Street Light
Standard
Bus Shelter - Elevations
Standard
Bus Shelter - Roof Plan
Bus Shelter
Floor/Foundation Plan
Standard
Bus Shelter Roof Section
Standard Bus Shelter Connection Details 1-3
Standard Bus Shelter Connection Details 4-6
Standard Bus Shelter Connection Details 7-9
Standard Bus Shelter Foundation Location Option
and Special Curb & Gutter.
Standard Mid-Block & Far Side Bus Pullout
Special Notes and Shelter Easement
Bus Shelter Power and Light
Detail
Private Street
Name Sign Diagram
Multi-Use Path Lighting Details
Multi-Use Path
at T-Intersections
Multi-Use Path Design and Lighting Details
Dual Load Center
Foundation Detail
Special Rio Salado
Multi-Path Lighting Fixture |
| |
Tempe Engineering Department
31 East 5th Street Tempe, AZ 85281
(480) 350-8200
Andy Goh
Deputy Public Works Manager / City Engineer |
|
|